co2piping.com
Knowledge base

Knowledge base for refrigeration and heat pump technicians

Laws, regulations and standards by country, step-by-step guides for common tasks and a glossary of the most common terms. Every article has sources with links to the official texts and the date it was last checked.

Laws, regulations and standards

International · Laws and regulationsRefrigerant rules by country: laws, leak checks, certificates, HFC taxes and bansRefrigerant rules in 27 countries and regions side by side: law and authority, leak-check threshold, technician certificate, HFC tax and key GWP bans with dates.EU · Laws and regulationsThe F-gas Regulation (EU) 2024/573: what it means for refrigeration and heat pumpsOverview of F-gas Regulation 2024/573: leak checks in tonnes CO2e, records, certification, service bans for GWP 2,500 and 750, product bans and the HFC phase-out.Sweden · Laws and regulationsSwedish refrigerant rules: Ordinance 2016:1128, notification and annual reportWhat applies in Sweden in addition to the EU F-gas Regulation: notification before installation, annual report by 31 March, supervision, fines, certification and changes under way.United Kingdom · Laws and regulationsUnited Kingdom: the F-gas rules after Brexit for refrigeration and heat pumpsWhat applies to refrigerants in the UK: Great Britain follows retained Regulation 517/2014, Northern Ireland the EU's 2024/573. Leak checks, certificates, service bans and quotas.Ireland · Laws and regulationsIreland refrigerant rules: S.I. 404/2022, EPA, certificates and pressure systemsWhat applies in Ireland on top of the EU F-gas Regulation: S.I. 404/2022, EPA enforcement and fixed payment notices, certification and the pressure system rules in S.I. 299/2007.USA · Laws and regulationsUSA: EPA Section 608, the AIM Act and the safety standards ASHRAE 15 and 34Refrigerant rules in the USA: Section 608 certification, leak repair from 50 and 15 lb, the AIM Act and Technology Transitions with the 2026 changes, ASHRAE 15/34 and UL 60335-2-40.Canada · Laws and regulationsCanada refrigerant rules: GWP limits, SOR/2016-137 and CSA B52Refrigerant rules in Canada: GWP limits by product type under SOR/2016-137, the federal halocarbon rules SOR/2022-110, provincial certificates such as Ontario’s and the CSA B52:23 code.Australia and New Zealand · Laws and regulationsAustralia and New Zealand: HFC phase-down, refrigerant handling licences and AS/NZS 5149Refrigerant rules in Australia and New Zealand: import quotas and the HFC phase-down to 2036, ARC licences and authorisations, the 2025 codes of practice and AS/NZS 5149.International · Laws and regulationsEN 378 and ISO 5149: safety classes, location classes and charge limitsThe safety standard for refrigerating systems and heat pumps: the four parts of EN 378, ISO 817 safety classes, location class, access category, charge limits, PS and the revision.International · Laws and regulationsSecondary cooling systems: rules for glycol, brine, CO2 and chilled waterIndirect cooling with glycol, brine, CO2 or chilled water: what EN 378, the EU F-gas Regulation, the Pressure Equipment Directive and Swiss law say about the secondary circuit.EU · Laws and regulationsPressure Equipment Directive PED 2014/68/EU: categories, modules and CE for refrigerationPED 2014/68/EU for refrigeration and heat pumps: PS, fluid groups 1 and 2, categories I–IV from PS·V and PS·DN, modules, notified body, CE marking, assemblies, EN 378-2.International · Laws and regulationsFlammable refrigerants (A2L and A3): charge limits, standards and ATEXHow propane, isobutane, R32 and other flammable refrigerants may be used: LFL, m1–m3 under EN 378, the room formula, IEC 60335-2-89 (13 × LFL), ATEX and safe servicing.Denmark · Laws and regulationsDenmark: refrigerant rules – HFC ban, HFC tax and KMO certificationWhat applies in Denmark in addition to the EU F-gas Regulation: national ban on HFC in new systems, a tax per kg of HFC, KMO certificates and the changes made in 2025–2026.Norway · Laws and regulationsNorway refrigerant rules: EEA, produktforskriften, HFC tax and certificationWhat applies in Norway: the EU F-gas rules via the EEA Agreement, produktforskriften chapter 6a, the 2026 HFC/PFC tax, refunds for destruction and certificates valid for five years.Finland · Laws and regulationsFinland refrigerant rules: Tukes qualifications, Decree 1063/2025 and supervisionWhat applies in Finland in addition to the EU F-gas Regulation: Environmental Protection Act, Decree 1063/2025, Tukes qualifications and registers, supervision, penalties, deadlines to 2029.Germany · Laws and regulationsGermany refrigerant rules: ChemKlimaschutzV 2026, certificates and leakage limitsWhat applies in Germany in addition to the EU F-gas Regulation: the new ChemKlimaschutzV from 17 April 2026, A1, B and C certificates, leakage limits, take-back, fines and pressure checks.Austria · Laws and regulationsAustria refrigerant rules: FTG 2009, certification, fines and pressure equipmentWhat applies in Austria on top of the EU F-gas Regulation: the Fluorierte Treibhausgase-Gesetz 2009, certification bodies, fines up to 38,000 euro and the DGÜW-V pressure checks.Spain · Laws and regulationsSpain: refrigerant rules, RD 115/2017, the F-gas tax and RD 552/2019What applies in Spain on top of the EU F-gas Regulation: RD 115/2017, regional certificates, empresas habilitadas, the tax of €0.015/kg per GWP unit and the new decree.France · Laws and regulationsFrance: refrigerant rules, attestation de capacité and fiche d'interventionWhat applies in France on top of the EU F-gas Regulation: company and technician attestations, the CERFA record, annual declaration, new categories from 2027 and the dropped HFC tax.Italy · Laws and regulationsItalian refrigerant rules: DPR 146/2018, the F-gas register and the Banca DatiWhat applies in Italy besides the EU F-gas Regulation: register at the Chambers of Commerce, reporting to the Banca Dati within 30 days, certification, penalties and status in 2026.Netherlands · Laws and regulationsNetherlands: refrigerant rules – F-gas Besluit, BRL 100, BRL 200 and STEKWhat applies in the Netherlands on top of the EU F-gas Regulation: the national Besluit and Regeling, BRL 200 personal certificates, BRL 100 company certificates and key dates 2025–2029.Hungary · Laws and regulationsHungary: refrigerant rules – climate gas act, NKVH certification and supervisory feeWhat applies in Hungary in addition to the EU F-gas Regulation: the 2025 climate gas act, the NKVH database, certificates for persons and companies, the supervisory fee and 2026 changes.Portugal · Laws and regulationsPortugal: refrigerant rules – Decreto-Lei 145/2017, APA certification and reportingWhat applies in Portugal in addition to the EU F-gas Regulation: Decreto-Lei 145/2017, certification of technicians and companies, annual reporting to APA and registration fees.Czechia · Laws and regulationsCzechia: refrigerant rules – Act 73/2012 Sb., certification and the 2026 amendmentWhat applies in Czechia in addition to the EU F-gas Regulation: Act 73/2012 Sb., the ban on disposable cylinders, certificates from designated bodies, ISPOP reporting and the 2026 amendment.Poland · Laws and regulationsPoland: refrigerant rules – the F-gas Act, the CRO register and UDT certificationWhat applies in Poland in addition to the EU F-gas Regulation: the 2015 F-gas Act, equipment records in the CRO register, UDT certificates, annual BDS reports and the expected new act.India · Laws and regulationsIndia: ODS Rules 2000, HCFC phase-out, Kigali (group 2) and the India Cooling Action PlanRefrigerant rules in India: ODS Rules 2000 with registration and licences, the HCFC ban in new equipment from 2025, the Kigali HFC freeze in 2028, ICAP and training of service technicians.Switzerland · Laws and regulationsSwitzerland refrigerant rules: ChemRRV Annex 2.10, refrigerant licence and reportingWhat applies in Switzerland: its own rules in ChemRRV Annex 2.10 instead of the EU F-gas Regulation, the Fachbewilligung, Wartungsheft, reporting duty and new bans from 2027.Türkiye · Laws and regulationsTurkey refrigerant rules: the 2024 F-gas regulation, certification and KigaliWhat applies in Turkey: its own 2024 F-gas regulation, leak checks and EKOMVET, MYK certificates for technicians, TSE certificates for firms, bans from 2027 and the Kigali HFC phase-down.Romania · Laws and regulationsRomania: refrigerant rules – Legea 120/2024, AGFR certificates and enforcementWhat applies in Romania in addition to the EU F-gas Regulation: Law 120/2024 on F-gases, enforcement by Garda Națională de Mediu, fines, AGFR certificates and the 2026 draft law.China · Laws and regulationsChina: ODS Regulations 2024, HFC quotas, Kigali (group 1), HCFC phase-out and GB standardsRefrigerant rules in China: ODS Regulations covering HFCs since 2024, annual MEE HFC quotas, the Kigali freeze in 2024 and −10 % by 2029, HCFC phase-out, filing for service firms, GB/T 9237.Japan · Laws and regulationsJapan: フロン排出抑制法, the Kigali HFC phase-down and the High Pressure Gas Safety ActRefrigerant rules in Japan: inspections and leak reports under フロン排出抑制法, disposal with certificates since 2020, HFC phase-down, GWP targets for units and 高圧ガス保安法.South Korea · Laws and regulationsSouth Korea: refrigerant rules in the Clean Air Conservation Act, HFC phase-down, KGSRefrigerant rules in South Korea: duties from 20 RT, annual leak checks, logbook and RIMS, registered recovery businesses, Kigali and the ozone act, pressure rules and KGS codes.Singapore · Laws and regulationsSingapore refrigerant rules: EPMA, NEA, GWP limits, registration and recoverySingapore's GWP limits under the EPMA and NEA rules for AC, fridges, chillers, commercial refrigeration and car AC, plus registration and records.Latin America · Laws and regulationsLatin America: HFC rules in Mexico, Colombia, Chile and Argentina (Kigali group 1)HFC rules in Mexico, Colombia, Chile and Argentina: Kigali group 1, national import quotas in CO2e, banned HFCs, importer licences and authorities.

Step-by-step guides

International · Step-by-step guideEN 13136: sizing relief valves and discharge lines in refrigerating systemsHow relief valves and discharge lines are sized to EN 13136: fire, compressor, heat source, Kdr and Kb, 3 % inlet loss, back pressure, CO2 and dry ice, and the successor EN ISO 24664.EU · Step-by-step guideLeak check of refrigeration systems: F-gas intervals and stepsLeak check step by step: intervals of 12, 6 or 3 months by tonnes CO2e, records, direct and indirect methods, EN 14624 detectors and the follow-up check after a repair.International · Step-by-step guideRefrigeration pressure test: strength and tightness test, step by stepStep-by-step pressure test for refrigerating systems: test pressure 1.1 or 1.43 × PS, nitrogen, danger zone, tightness test, safety and what goes in the test certificate.International · Step-by-step guideEvacuating a refrigerating system step by step: dehydration and standing vacuum testHow to evacuate a refrigerating system: the right equipment, a target of 500 microns (0.67 mbar), a standing test that tells moisture from leaks, triple evacuation with nitrogen and common mistakes.International · Step-by-step guideSuperheat and subcooling: how to measure and interpret them, including glideStep by step: measure superheat and subcooling correctly, use the dew point and bubble point for blends with glide (R407C, R448A, R449A), and interpret the values when troubleshooting.International · Step-by-step guideSwitching from HFC to CO2 (R744) or propane (R290) step by stepMoving a plant from HFC to CO2 or propane: why you cannot just refill, system choice, EN 378 charge limits, PED, ATEX, certificates and start-up.International · Step-by-step guideCO2 (R744) transcritical systems: a practical service guideHow to service transcritical CO2 systems safely: pressures, dry ice and the triple point, trapped liquid, recovery, charging, testing and the EU rules for certificate B.International · Step-by-step guideRefrigeration tool list: what technicians and CO2 installers needThe tools a refrigeration technician needs, from gauges and vacuum pump to leak detector and PPE, with the ratings and approvals to check for CO2 and for A2L and A3 refrigerants.

Troubleshooting

Glossary A–Z

About the knowledge base

The articles are written by CO2piping.com for technicians, designers and plant owners. Every statement about requirements, limits or dates refers to a source, first of all the official legal text or the publisher of the standard, and every article shows when it was last checked.

Rules change. When a law or standard is being revised, the article says so. Always check the text in force before you make decisions, and ask the competent authority if you are unsure.

Found a mistake or missing a topic? Write to Co2Calc@proton.me.

New feature – please report any errors: Report a bug